Yokogawa Temperature Transmitter YTA110

Yokogawa Temperature Transmitter YTA110

Supports input of thermocouple, thermal resistance, DC voltage or resistance signals.
Converted to 4-20 mA DC signal or fieldbus signal output.
It is divided into HART communication type and FOUNDATIONTM fieldbus communication type.
The HART communication type complies with SIL2 safety level.

Product Details: Yokogawa Temperature Transmitter YTA110

The YTA110/310 is a field-mount temperature transmitter that accepts a single sensor input and YTA320 is a dual inputs.
This input can be from a RTD, thermocouple, ohm, or DC millivolt. These models support BRAIN communication protocol. Dual input functions include Failed Sensor Backup, Temperature Averaging, and Differential Temperature.

product-1259-709

product-1132-841

Product Features:

The Yokogawa Temperature Transmitter Yta110 stands apart for its chip based detecting innovation, which guarantees long haul exactness and high unwavering quality. It is outfitted with a double compartment lodging that offers hearty protection from unforgiving conditions, and it is confirmed SIL2 by TÜV, meeting rigid security prerequisites. The transmitter upholds both Cerebrum and HART correspondence conventions, taking into account adaptable and productive design and correspondence. Its self-diagnostics capability is a fundamental element that ensures constant execution and lessens the all out cost of proprietorship. The LCD show with a structured presentation gives an unmistakable and quick visual sign of the temperature readings.

Technical Specifications:

Specification Details
Accuracy ±0.1% of calibrated span or A/D accuracy/span + D/A accuracy, whichever is greater
Cold Junction Compensation (CJC) ±0.5°C (±0.9°F) for T/C only
Ambient Temperature Effect ±0.1% or ± (Temperature Coefficient /span) per 10°C change
Stability (RTD) ±0.1% of reading or ± 0.1°C per 2 years, whichever is greater at 23±2°C
Stability (T/C) ±0.1% of reading or ± 0.1°C per year, whichever is greater at 23±2°C
Power Supply Effect ±0.005% of calibration span per volt
Vibration Effect 0.21 mm peak displacement at 10 to 60 Hz, 3G at 60 to 2000 Hz
Position Effect None
Update Time Approximately 0.5 seconds
Turn-on Time Approximately 5 seconds
Damping Time Constant Selectable from 0 to 99 seconds
Ambient Temperature Limits -40 to 85°C (-40 to 185°F) with Integral Indicator, -30 to 80°C (-22 to 176°F) without
Humidity Limits 5 to 100% RH at 40°C (104°F)
EMC Conformity EN61326-1 Class A, EN61326-2-3

Product Highlights:

High level Detecting Innovation: The Yokogawa Temperature Transmitter Yta110 uses state of the art chip based innovation for upgraded precision and unwavering quality after some time.
Double Compartment Lodging: This plan guarantees high protection from brutal conditions, safeguarding the inside parts and keeping up with execution.
Wellbeing Accreditation: SIL2 affirmation by TÜV gives confirmation of the gadget's security abilities in basic applications.
Adaptable Correspondence Choices: Support for Mind and HART conventions empowers simple combination into existing frameworks and considers distant setup.
Self-Diagnostics: The implicit self-diagnostics capability screens the transmitter's wellbeing, making aware of likely issues before they influence execution.
Clear Showcase: The LCD show with a reference diagram offers a reasonable, initially perspective on temperature readings and framework status.

Packaging and Shipping:

The product is painstakingly bundled to guarantee safe transportation and conveyance. Every unit is safely encased in defensive bundling material and delivered as per worldwide transportation principles to forestall any harm during travel.

product-1-1

Contact Us:

Shaaxi ZYY is a specialist instrument association invest critical energy in the arrangements of premium brands like Emerson, Rosemount, Yokogawa, E+H, Azbil, Fisher, Honeywell, ABB, Siemens, and that is only the start. With over 10 years of contribution as a supplier, we offer a broad assortment of thing models and are centered around offering capable responses for our clients. For all the more thing assessing information or to discuss your specific essentials, please contact us at lm@zyyinstrument.com.

YOU MAY LIKE

Fisher Valve Positioner DVC6200

Fisher Valve Positioner DVC6200

The Fisher FIELDVUE DVC6200 valve Positioner allows equipment to operate as close to the set point as possible for more accurate control and improved product quality. Monitor valve operation online with FIELDVUE performance diagnostics to assess performance and reliability.
View More
Rosemount™ 3144P temperature transmitter

Rosemount™ 3144P temperature transmitter

Rosemount 3144P temperature transmitter provides you with industry-leading temperature measurements with accuracy, stability and reliability. The transmitter's dual chamber housing ensures reliability and advanced diagnostics to keep your measuring points up and running. The transmitter combines Rosemount X-well™ technology with the Rosemount 0085 clamp sensor to accurately measure process temperature, eliminating the need for hot tubing or process penetration.
View More
Rosemount™ 248 rail-mounted temperature transmitter

Rosemount™ 248 rail-mounted temperature transmitter

The Rosemount 248 temperature transmitter, as an industry standard solution, can provide consistent and reliable performance in the process environment. The compact DIN rail design is easy to install and widely applicable, meeting common single-point temperature measurement requirements.
View More
Yokogawa Temperature Transmitter YTA710

Yokogawa Temperature Transmitter YTA710

The YTA710 features high precision, high stability and high reliability. The shell structure adopts a reliable double-chamber structure. The sensor input can be selected as single input or dual input. It can accept various input signals such as RTD, thermocouple, resistance, and DC voltage. It converts the sensor input into a 4-20 mA DC analog signal or a fieldbus digital signal. HART 7 protocol, BRAIN protocol or FOUNDATION™ Fieldbus ITK 6 version are provided. Dual input can accept the differential or average calculation of two sensors and also realize the sensor backup function. The sensor backup function is used to automatically switch from the main device to the backup device when the sensor malfunctions. The on-site parameters can be set by using the on-site parameters button on the indicator.
View More
Yokogawa Temperature Transmitter YTA610

Yokogawa Temperature Transmitter YTA610

The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure. By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
View More
Rosemount 3051GP pressure transmitter

Rosemount 3051GP pressure transmitter

The 3051GP pressure transmitter has first-class performance, with a standard reference accuracy of 0.05% and a 10-year stability. The range ratio is 100:1. Through this coplanar platform, an integrated pressure, flow and liquid level solution can be achieved. SIL2 safety certification was carried out in accordance with the IEC 61508 standard. Due to the comprehensive HART® function, the safety verification was simplified.
View More
Rosemount™ 644 temperature transmitter

Rosemount™ 644 temperature transmitter

Rosemount 644 temperature transmitters are versatile and available using HART™, FOUNDATION™ Fieldbus or PROFIBUS™ protocols, with top, field or rail mount styles and multiple housing options. By adding a Local Operator Interface (LOI), the transmitter configuration can be updated in the field without tools. The transmitter also includes diagnostic functions such as Hot Backup™, sensor drift warning and thermocouple performance degradation to meet different application requirements.
View More
Rosemount 214c Temperature Sensor

Rosemount 214c Temperature Sensor

The Rosemont 214C thermistor temperature sensor uses a Pt-100 unit or dual-element thermistor (RTD), covering a temperature range from -196 to 600°C (-321 to 1112°F). This sensor is a special solution that adopts a thin-film and wound design, enhancing application flexibility. This sensor has many calibration options, including Grade A or Grade B sensor accuracy, and also provides the Callendar-Van Dusen constant for transmitter - sensor matching to achieve high precision.
View More